M32F
M32F:
- Ultra compact 3 phase ACCLs with interlocked contactor design.
- Just 101mm wide (less than 6 MCBs wide)
- Pure white FR polycarbonate enclosure with fine, custom-made terminals for better operation and aesthetics.
- DG Limits can be set at factory on order, and can also be set on-site.
Rated Loads | 32A, FP (EB); 32A, FP(DG) |
Suited for | Power + Lighting loads |
Dimensions (WxHxD) | 101 x 150 x 124 mm |
Switching device | Contactor |
No. of Poles | 4 (3P+N) |
Rated Voltage | 415V (L-L) / 240V (P-N), 50 Hz. |
Mains Rated Current (AC1) | 32A |
Mains Rated Current (AC3) | 18A |
Generator Trip Range (AC1) | 1-32A |
Starting Voltage Range (Mains, P-N) | 180-300V |
Operating Voltage Range (Mains, P-N) | 180-300V (310-520V L-L) |
Operating Voltage Range (Gen, P-N) | 170-250V |
Generator output on-delay | 4-10 seconds, randomized on boot-up |
Transfer Time | 1 second |
Self-resetting Time (after tripping) | 4-10 seconds |
Under/over-voltage Protection (Mains) | Optional |
Under/over-voltage Protection (Gen) | Yes, 170-270V |
Utilisation Category | AC1 / AC7a / AC7b |
Electrical Endurance (Operations) | 60,000 |
Enclosure Material | Polycarbonate (Fire-retardant) |
Mounting Type | DIN (35mm) |
Terminal Capacity | 16 mm2 |
Dimensions in mm (W x H x D) | 101 x 150 x 124 |
Weight | 1.1 KG |
Conformity | IEC 60947-4 / IEC 60947-6-1 |
Protection Class | IP20 |
Ambient Temperature | -10° – 65°C |
Rated Insulation Voltage | 1.1 kV |
Load Switching Device | Interlocked Dual Contactor |
Short-circuit withstand capacity | 6kA |
Optional on-demand features | Generator output lock-out; On-site reconfiguration |
M45F
M45F:
- Time-tested 3 phase ACCLs with interlocked contactor design for complete safety and seamless operation.
- Superb performance track-record.
- Pure white FR polycarbonate enclosure with fine, custom-made terminals for better operation and aesthetics.
Rated Loads | 45A, FP (EB); 45A, FP (DG) |
Suited for | Lighting + power loads. |
Dimensions (WxHxD) | 122 x 157 x 148 mm |
Switching device | Contactor |
No. of Poles | 4 (3P+N) |
Rated Voltage | 415V (L-L) / 240V (P-N), 50 Hz. |
Mains Rated Current (AC1) | 45A |
Mains Rated Current (AC3) | 25A |
Generator Trip Range (AC1) | 1-45A |
Starting Voltage Range (Mains, P-N) | 180-300V |
Operating Voltage Range (Mains, P-N) | 180-300V (310-520V L-L) |
Operating Voltage Range (Gen, P-N) | 170-250V |
Generator output on-delay | 4-10 seconds, randomized on boot-up |
Transfer Time | 1 second |
Self-resetting Time (after tripping) | 4-10 seconds |
Under/over-voltage Protection (Mains) | Optional |
Under/over-voltage Protection (Gen) | Yes, 170-270V |
Utilisation Category | AC1 / AC7a / AC7b |
Electrical Endurance (Operations) | 60,000 |
Enclosure Material | Polycarbonate (Fire-retardant) |
Mounting Type | DIN (35mm / 75 mm) |
Terminal Capacity | 16 mm2 |
Dimensions in mm (W x H x D) | 122 x 157 x 148 |
Weight | 1.54 KG |
Conformity | IEC 60947-4 / IEC 60947-6-1 |
Protection Class | IP20 |
Ambient Temperature | -10° – 65°C |
Rated Insulation Voltage | 1.1 kV |
Load Switching Device | Interlocked Dual Contactor |
Short-circuit withstand capacity | 6kA |
Optional on-demand features | Generator output lock-out; On-site reconfiguration |
M63FS
M63FS:
- All-new 63A three-phase ACCL in the same compact size as M45F!
- Great for projects where panel size and cost are constrained.
- Pure white FR polycarbonate enclosure with fine, custom-made terminals for better operation and aesthetics.
Rated Loads | 63A, FP (EB); 63A, FP (DG) |
Suited for | Lighting + power loads. |
Dimensions (WxHxD) | 122 x 157 x 148 mm |
Switching device | Contactor |
No. of Poles | 4 (3P+N) |
Rated Voltage | 415V (L-L) / 240V (P-N), 50 Hz. |
Mains Rated Current (AC1) | 63A |
Mains Rated Current (AC3) | – |
Generator Trip Range (AC1) | 1-63A |
Starting Voltage Range (Mains, P-N) | 180-300V |
Operating Voltage Range (Mains, P-N) | 180-300V (310-520V L-L) |
Operating Voltage Range (Gen, P-N) | 170-250V |
Generator output on-delay | 4-10 seconds, randomized on boot-up |
Transfer Time | 1 second |
Self-resetting Time (after tripping) | 4-10 seconds |
Under/over-voltage Protection (Mains) | Optional |
Under/over-voltage Protection (Gen) | Yes, 170-270V |
Utilisation Category | AC1 / AC7a / AC7b |
Electrical Endurance (Operations) | 60,000 |
Enclosure Material | Polycarbonate (Fire-retardant) |
Mounting Type | DIN (35mm / 75 mm) |
Terminal Capacity | 16 mm2 |
Dimensions in mm (W x H x D) | 122 x 157 x 148 |
Weight | 1.6 KG |
Conformity | IEC 60947-4 / IEC 60947-6-1 |
Protection Class | IP20 |
Ambient Temperature | -10° – 65°C |
Rated Insulation Voltage | 1.1 kV |
Load Switching Device | Interlocked Dual Contactor |
Short-circuit withstand capacity | 6kA |
Optional on-demand features | Generator output lock-out; On-site reconfiguration |
M63F / M70F
M63F / M70F:
- High current capacity ACCLs for luxury residential and commercial projects, using heavy-duty contactors for supreme robustness and reliability.
- Fire-retardant polycarbonate body – unique in its class!
- Option for both DIN-channel and surface mounting.
- Double-screw terminals for secure connections.
Rated Loads (EB & DG) | M63F: 63A FP;
M70F: 70A, FP |
Suited for | Lighting + power loads. |
Dimensions (WxHxD) | 185 x 220 x 180 mm |
Switching device | Contactor |
No. of Poles | 4 (3P+N) |
Rated Voltage | 415V (L-L) / 240V (P-N), 50 Hz. |
Mains Rated Current (AC1) | M63F: 63A; M70F: 70A |
Mains Rated Current (AC3) | M63F: 40A; M70F: 50A |
Generator Trip Range (AC1) | M63F: 1-63A; M70F: 1-70A |
Starting Voltage Range (Mains, P-N) | 180-300V |
Operating Voltage Range (Mains, P-N) | 180-300V (310-520V L-L) |
Operating Voltage Range (Gen, P-N) | 170-250V |
Generator output on-delay | 4-10 seconds, randomized on boot-up |
Transfer Time | 1 second |
Self-resetting Time (after tripping) | 4-10 seconds |
Under/over-voltage Protection (Mains) | Optional |
Under/over-voltage Protection (Gen) | Yes, 170-270V |
Utilisation Category | AC1 / AC7a / AC7b |
Electrical Endurance (Operations) | 60,000 |
Enclosure Material | Polycarbonate (Fire-retardant) |
Mounting Type | DIN (35mm / 75 mm) / Surface |
Terminal Capacity | 35 mm2 |
Dimensions in mm (W x H x D) | 185 x 220 x 180 |
Weight | 3.6 KG |
Conformity | IEC 60947-4 / IEC 60947-6-1 |
Protection Class | IP20 |
Ambient Temperature | -10° – 65°C |
Rated Insulation Voltage | 1.1 kV |
Load Switching Device | Interlocked Dual Contactor |
Short-circuit withstand capacity | 6kA |
Optional on-demand features | Generator output lock-out; On-site reconfiguration |
ATS 80
ATS 80:
In addition to standard 3 phase ACCL functionality, ATS models offer features such as continuous monitoring of all three-phase voltages and giving priority to DG in case any of the EB phases are unhealthy, acting as a mains single-phasing preventer (when DG is on). The ATS 80 comes in the same FRPC body as M70F, whereas the ATS 125 is built in a robust sheet-metal enclosure
Rated Loads | 80A/125A |
Suited for | Lighting + power loads. |
Dimensions (WxHxD) | 185 x 220 x 180 mm |
Switching device | Contactor |
No. of Poles | 4 (3P+N) |
Rated Voltage | 415V (L-L) / 240V (P-N), 50 Hz. |
Mains Rated Current (AC1) | 80A |
Mains Rated Current (AC3) | 65A |
Generator Trip Range (AC1) | 1-80A |
Starting Voltage Range (Mains, P-N) | 180-300V |
Operating Voltage Range (Mains, P-N) | 180-300V (310-520V L-L) |
Operating Voltage Range (Gen, P-N) | 170-250V |
Generator output on-delay | 4-10 seconds, randomized on boot-up |
Transfer Time | 1 second |
Self-resetting Time (after tripping) | 4-10 seconds |
Under/over-voltage Protection (Mains) | Optional |
Under/over-voltage Protection (Gen) | Yes, 170-270V |
Utilisation Category | AC1 / AC7a / AC7b |
Electrical Endurance (Operations) | 60,000 |
Enclosure Material | Polycarbonate (Fire-retardant) |
Mounting Type | DIN (35mm / 75 mm) / Surface |
Terminal Capacity | 35 mm2 |
Dimensions in mm (W x H x D) | 185 x 220 x 180 |
Weight | 3.8 KG |
Conformity | IEC 60947-4 / IEC 60947-6-1 |
Protection Class | IP20 |
Ambient Temperature | -10° – 65°C |
Rated Insulation Voltage | 1.1 kV |
Load Switching Device | Interlocked Dual Contactor |
Short-circuit withstand capacity | 6kA |
Optional on-demand features | Generator output lock-out; On-site reconfiguration |
ATS 125
ATS 125:
In addition to standard 3 phase ACCL functionality, ATS models offer features such as continuous monitoring of all three-phase voltages and giving priority to DG in case any of the EB phases are unhealthy, acting as a mains single-phasing preventer (when DG is on). ATS 125 is built in a robust sheet-metal enclosure.
Rated Loads | 125A, FP |
Suited for | Lighting + power loads. |
Dimensions (WxHxD) | 265 x 250 x 165 mm |
Switching device | Contactor |
No. of Poles | 4 (3P+N) |
Rated Voltage | 415V (L-L) / 240V (P-N), 50 Hz. |
Mains Rated Current (AC1) | 125A |
Mains Rated Current (AC3) | 95A |
Generator Trip Range (AC1) | 1-125A |
Starting Voltage Range (Mains, P-N) | 180-300V |
Operating Voltage Range (Mains, P-N) | 180-300V (310-520V L-L) |
Operating Voltage Range (Gen, P-N) | 170-250V |
Generator output on-delay | 4-10 seconds, randomized on boot-up |
Transfer Time | 1 second |
Self-resetting Time (after tripping) | 4-10 seconds |
Under/over-voltage Protection (Mains) | Optional |
Under/over-voltage Protection (Gen) | Yes, 170-270V |
Utilisation Category | AC1 / AC7a / AC7b |
Electrical Endurance (Operations) | 60,000 |
Enclosure Material | Sheet-metal |
Mounting Type | Surface |
Terminal Capacity | 35 mm2 |
Dimensions in mm (W x H x D) | 215 x 265 x 185 |
Weight | 6.5 KG |
Conformity | IEC 60947-4 / IEC 60947-6-1 |
Protection Class | IP20 |
Ambient Temperature | -10° – 65°C |
Rated Insulation Voltage | 1.1 kV |
Load Switching Device | Interlocked Dual Contactor |
Short-circuit withstand capacity | 6kA |